logo
Evde > Ürünler >
Kablo hatası belirleyici
>
Industrial Grade Portable Cable Fault Simulation Device for Testing and Diagnostics

Industrial Grade Portable Cable Fault Simulation Device for Testing and Diagnostics

Ürün Ayrıntıları:
Menşe yeri: Xi'an Shaanxi
Marka adı: XZH TEST
Sertifika: ISO
Model numarası: XHGG510S
Ayrıntılı Bilgiler
Menşe yeri:
Xi'an Shaanxi
Marka adı:
XZH TEST
Sertifika:
ISO
Model numarası:
XHGG510S
Vurgulamak:

High Light

Vurgulamak:

Industrial Grade Cable Fault Simulation Device

,

Portable Cable Fault Locator

,

Simulation Cable Tester

Trading Information
Min sipariş miktarı:
1 takım
Ambalaj bilgileri:
ahşap ambalaj
Teslim süresi:
5-8 İŞ GÜNÜ
Ödeme koşulları:
T/T
Yetenek temini:
3000 birim/yıl
Ürün Tanımı
XHGG510S
As urbanization speeds up, urban scales expand and electricity demand grows year by year, making cable lines the preferred replacement for the outdated single overhead power lines. For years, training and popularizing power cable fault detection professionals has remained a key difficulty. Addressing this, our company has developed a proprietary power cable fault simulator that can replicate all types of cable faults. This device integrates the core experience accumulated over decades in China's power cable fault detection industry.

Main Technical Parameters:

1. Low Resistance Fault Simulator: 0Ω~Several Hundreds of Ω

2. Open Circuit Fault Simulator: Several Ω~∞

3. Leakage High Resistance Fault Simulator: Several Ω~Hundreds of MΩ

4. Flashover High Resistance Fault Simulator: Flashover Voltage Range Several kV~Hundreds of kV

5. Continuous Operating Time: 8 hours

6. Operating Conditions:

a. Ambient Temperature: -30℃~ +70℃

b. Relative Humidity (RH) ≤ 85% (25℃)

c. Altitude: h ≤ 1000m

Industrial Grade Portable Cable Fault Simulation Device for Testing and Diagnostics 0

Simulation Box Structure This power cable fault simulator box consists of four different types of fault simulators (low resistance, open circuit, high leakage resistance, and high flashover resistance). They are arranged parallel to each other within the simulation box, and are insulated from each other and from ground by support insulators mounted on elbow-shaped plug-in components inside the box.

Industrial Grade Portable Cable Fault Simulation Device for Testing and Diagnostics 1

Instructions for Use
Composition of the Simulated Fault Circuit: The simulated fault circuit consists of two cable reels connected in series to the cable fault simulator box.