logo
Evde > Ürünler >
ac dc hipot tester
>
High Precision VLF Tan Delta Tester, AC DC Withstand Voltage Test Device for Cable

High Precision VLF Tan Delta Tester, AC DC Withstand Voltage Test Device for Cable

Ürün Ayrıntıları:
Menşe yeri: Xi'an, Shaanxi, Çin
Marka adı: XZH TEST
Sertifika: ISO,CE
Model numarası: XHDP Serisi
Ayrıntılı Bilgiler
Menşe yeri:
Xi'an, Shaanxi, Çin
Marka adı:
XZH TEST
Sertifika:
ISO,CE
Model numarası:
XHDP Serisi
Vurgulamak:

High Light

Vurgulamak:

VLF Tan Delta Tester for cable

,

AC DC withstand voltage tester

,

High precision hipot test device

Trading Information
Min sipariş miktarı:
1 adet
Fiyat:
Anlaşılabilir
Ambalaj bilgileri:
ahşap ambalaj
Teslim süresi:
8-10 gün
Ödeme koşulları:
T/T
Yetenek temini:
2000 birim/yıl
Ürün Tanımı
General Description

XHDP series VLF high voltage generators integrate digital frequency conversion and intelligent microcomputer control systems. The whole testing process of voltage adjustment, data monitoring and safety protection is fully automatic. Its portable structure saves space, and the large LCD monitor delivers clear visual information. Meanwhile, it supports real-time output waveform display and test report printing for convenient data recording.

Functional Characteristics
  • High-voltage side sampling is available for current, voltage and waveform signal acquisition.
  • Independent over-current and over-voltage safety protection with rapid response below 20ms.
  • Closed-loop negative feedback circuit for high and low voltage is applied to avoid output capacitive rise phenomenon.
Technical Indicators
  • Nominal Output Voltage: 30kV, 50kV, 80kV; Accuracy Class: 3%
  • Working Frequency: 0.1Hz / 0.05Hz / 0.02Hz
  • Loading Performance: 1.1μF Max(0.1Hz), 2.2μF Max(0.05Hz), 5.5μF Max(0.02Hz)
  • Positive & Negative Peak Error of Voltage: ≤3%
  • Distortion of Voltage Waveform: ≤5%
  • Application Environment: Temp: -10℃~+40℃; Humidity: ≤85% RH
  • Mains Power: 220V±5%, 50Hz AC

    High Precision VLF Tan Delta Tester, AC DC Withstand Voltage Test Device for Cable 0