logo
Evde > Ürünler >
ac dc hipot tester
>
Portable VLF AC DC Tan Delta Tester, 0.1Hz High Voltage Insulation Test Equipment

Portable VLF AC DC Tan Delta Tester, 0.1Hz High Voltage Insulation Test Equipment

Ürün Ayrıntıları:
Menşe yeri: Xi'an, Shaanxi, Çin
Marka adı: XZH TEST
Sertifika: ISO,CE
Model numarası: XHDP Serisi
Ayrıntılı Bilgiler
Menşe yeri:
Xi'an, Shaanxi, Çin
Marka adı:
XZH TEST
Sertifika:
ISO,CE
Model numarası:
XHDP Serisi
Güç kaynağı:
50Hz Frekans, 220V±%5 Gerilim
Çalışma Ortamı:
Sıcaklık -10°C~+40°C; Nem ≤85%RH
Gerilim Dalga Biçimi Bozulması:
≤% 5
Pozitif ve Negatif Tepe Gerilim Hatası:
≤%3
Yük Kapasitesi:
Maksimum 1,1μF@0,1Hz, Maksimum 2,2μF@0,05Hz, Maksimum 5,5μF@0,02Hz
Vurgulamak:

High Light

Vurgulamak:

Portable VLF Tan Delta Tester

,

0.1Hz High Voltage Insulation Tester

,

AC DC Hipot Test Equipment

Trading Information
Min sipariş miktarı:
1 adet
Fiyat:
Anlaşılabilir
Ambalaj bilgileri:
ahşap ambalaj
Teslim süresi:
8-10 gün
Ödeme koşulları:
T/T
Yetenek temini:
2000 birim/yıl
Ürün Tanımı
Product Overview

The XHDP series ultra-low frequency high-voltage generator adopts modern digital frequency conversion technology and microcomputer automatic control. It realizes automatic voltage rise, voltage drop, measurement and protection functions. This device features compact size, light weight and large-screen LCD display. It presents data clearly and intuitively, supports output waveform display and test report printing.

Performance Features
  • Current, voltage and waveform data can all be sampled from the high-voltage side.
  • Equipped with over-current and over-voltage protection, with response time within 20ms.
  • Adopts high and low voltage closed-loop negative feedback control circuit, eliminating the capacitance rise effect of output voltage.
Technical Parameters
  1. Rated Output Voltage: 30kV/50kV/80kV, Accuracy: 3%
  2. Output Frequency: 0.1Hz, 0.05Hz, 0.02Hz
  3. Load Capacity: Max 1.1μF@0.1Hz, Max 2.2μF@0.05Hz, Max 5.5μF@0.02Hz
  4. Positive & Negative Peak Voltage Error: ≤3%
  5. Voltage Waveform Distortion: ≤5%
  6. Operating Environment: Temperature -10℃~+40℃; Humidity ≤85%RH
  7. Power Supply: 50Hz Frequency, 220V±5% Voltage