logo
Evde > Ürünler >
Kablo hatası belirleyici
>
High Voltage Surge Generator with 1024J Discharge Energy

High Voltage Surge Generator with 1024J Discharge Energy

Ürün Ayrıntıları:
Menşe yeri: Xi'an Shaanxi Çin
Marka adı: XZH TEST
Sertifika: ISO CE
Model numarası: XHHV535-2TS
Ayrıntılı Bilgiler
Menşe yeri:
Xi'an Shaanxi Çin
Marka adı:
XZH TEST
Sertifika:
ISO CE
Model numarası:
XHHV535-2TS
Vurgulamak:

High Light

Vurgulamak:

1024J Discharge Energy High Voltage Surge Generator

,

Built-in Capacitor 2μF Underground Cable Fault Locator

,

High Voltage Testing Cable Fault Detection Equipment

Trading Information
Min sipariş miktarı:
1 takım
Ambalaj bilgileri:
ahşap ambalaj
Teslim süresi:
5-8 İŞ GÜNÜ
Ödeme koşulları:
T/T
Yetenek temini:
3000 birim/yıl
Ürün Tanımı

XHHV535-2TS

This device is a high-end, trolley-type experimental instrument that integrates a DC high-voltage source, energy storage capacitor, discharge sphere device, automatic discharge device, and voltage level switching device into one unit. This equipment completely solves the problems of ease of use, portability, and safety and reliability associated with traditional experimental devices.


Technical Parameters

Impulse High Voltage: 0~32kV, 0~16kV, 0~8kV (3-level adjustment)

High Voltage Side Current: 0~60mA

High Voltage Accuracy: Class 2.5

Built-in Capacitor: 2μF/32kV, 8μF/16kV, 32μF/8kV (3-level adjustment)

Discharge Energy: 1024J (all)

Output Voltage Polarity: Negative

Impulse Time: Automatic impulse approximately 7 seconds, manual impulse with arbitrary controllable time

Overcurrent Protection: 9A (greater than 5S) on the low voltage side

Overtemperature Protection: 105℃

Maximum Power: 2000W

Operating Power Supply: AC 220V±10% 50Hz±2Hz

Ambient Temperature: -25~+65℃

High Voltage Surge Generator with 1024J Discharge Energy 0


Instrument Components:

1. High-voltage pulse generator main unit: Applyes high voltage and high-energy pulse signals to the cable under test;

2. High-voltage output cable (5 meters): Connects the high-voltage output terminal of the main unit to the core of the cable under test;

3. Ground wire (5 meters): Grounding wire for sampling, high-voltage ground, and discharge rod;

4. Power cord (1.8 meters): Instrument operating power cord;

5. Discharge rod: Performs DC current-limited discharge or DC short-circuit discharge on the cable under test;

6. Fuse: Backup fuse for AC220V power supply system (8A fuse).


High Voltage Surge Generator with 1024J Discharge Energy 1